Active carbon filter Hyperfiltre for MCH30 to MCH36 MK1 et MK2 COLTRI
Filtration cartridge Hyperfilter for breathing air compressors MCH30 to MCH36 COLTRI
Several models of cartridges are available depending on the use of the compressor (Choose from the list below the price of the item):
- Breathing air electric compressor: (Active Carbon / Molecular Sieve)
- Breathing air petrol compressor: model (Activated Carbon / Molecular Sieve / Carbon Monoxide Fixer)
- Breathing air compressor with CO charged atmosphere: model (Active Carbon / Molecular Sieve / Carbon Monoxide Fixer)
- Helium, Argon, Nitrogen Compressor: Model (Activated Carbon)
- Industrial dry air compressor: model (Molecular Sieve)
.
Compatibility:
MCH30, MCH36 (provide 1 AC/TM cartridge + 1 TM cartridge)
MCH13-16-18 Super Silent Mark I (include an AC/TM cartridge)
MCH13-16-18 Super Silent Mark II (provide one CA/TM cartridge + 1 TM cartridge)
MCH13-16-18 Compact Mark I (provide an AC/TM cartridge)
MCH13-16-18 Compact Mark II (provide 1 AC/TM + 1 TM cartridge)
MCH13-16-SH MINI TECH or TECH (provide an AC/TM/CO cartridge)
AUTONOMY:
As with any type of compressor of any brand, the range is variable depending on the inlet temperature of the cartridge and the flow rate of the compressor on which the cartridge is installed.
Attention, in the commercial brochures of presentation of the compressors, the various manufacturers always announce a autonomy of cartridge for a temperature at the entrance of filter of 20 ° C, this standardized standard temperature does not reflect unfortunately the reality under normal operating conditions. Thus the announced autonomies are still largely overestimated compared to the real autonomies when one takes into account the factor "temperature at the entrance of filter or separator". Some actors even playing on the confusion between local temperature (or suction) and the temperature of the cartridge inlet.
Indeed, the temperature at the cartridge inlet is not equal to the inlet temperature of the compressor. In general, it is always necessary to add at least between 10 and 20 ° C between the air inlet temperature of the compressor and the temperature at the filter inlet. For a perfectly ventilated room, the temperature delta between the inlet temperature of the compressor and the inlet temperature in the cartridge will be around 10 ° C. For a poorly ventilated room (temperature rise in the room of more than 10 ° C after 30 minutes of operation), the delta of temperature between the inlet temperature of the compressor and the inlet temperature in the cartridge will be approximately 20 ° C.
Example:
Room temperature before starting the compressor: 20 ° C
Room temperature after 30 minutes of operation: 30 ° C
The temperature at the cartridge inlet will therefore be 40 ° C. It is this temperature that must be taken as a reference for autonomy. With an MCH16, the autonomy of the cartridge will be 14 hours.
COMPRESSOR MCH8
cartridge inlet temperature of 20 ° C: 70 hours of operation
cartridge inlet temperature of 30 ° C: 40 hours of operation
cartridge inlet temperature of 40 ° C: 24 hours of operation
cartridge inlet temperature of 50 ° C: 14 hours of operation
COMPRESSOR MCH11
cartridge inlet temperature of 20 ° C: 55 hours of operation
cartridge inlet temperature of 30 ° C: 31 hours of operation
cartridge inlet temperature of 40 ° C: 19 hours of operation
cartridge inlet temperature of 50 ° C: 11 hours of operation
COMPRESSOR MCH13 - MCH26
cartridge inlet temperature of 20 ° C: 50 hours of operation
cartridge inlet temperature of 30 ° C: 28 hours of operation
cartridge inlet temperature of 40 ° C: 17 hours of operation
cartridge inlet temperature of 50 ° C: 10 hours of operation
COMPRESSOR MCH16 - MCH32
cartridge inlet temperature of 20 ° C: 40 hours of operation
cartridge inlet temperature of 30 ° C: 23 hours of operation
cartridge inlet temperature of 40 ° C: 14 hours of operation
cartridge inlet temperature of 50 ° C: 8 hours of operation
COMPRESSOR MCH18
cartridge inlet temperature of 20 ° C: 36 hours of operation
cartridge inlet temperature of 30 ° C: 20 hours of operation
cartridge inlet temperature of 40 ° C: 12 hours of operation
cartridge inlet temperature of 50 ° C: 7 hours of operation
CHARGING:
COL36-07-034 cartridges with aluminum body can be reconditioned up to 10 times.
CAUTION:
A saturated filter cartridge can cause serious malfunctions on the compressor (explosion of cartridges, tightening of the last stage piston, etc.) and restore air that does not meet the breathable air standard EN12021-2014.